Hardness Test

Vickers hardness test method was done in four different zones of Base Metal, weld metal and two points from Heat Affected Zone (HAZ) with 10 kgf. The results are shown in the following table.

 

Sample

Force (kg.f.)

Position

Hardness (HV)

Result

Zone 1

10

BM

203,203,207

Accept

Zone 2

10

BM

203,203,207

Accept

Zone 3

10

HAZ-2

209,206,202

Accept

Zone 4

10

HAZ-1

224,216,222

Accept